Application conditions

Electroplate power should be used indoors, and the application conditions are as follows:

 ●No more than 1000 meters above sea level;

 ●Environment must be free of acid, alkali and other corrosive gases or other harmful ,flammable and explosive gases;

 ●Working ambient temperature should be in the range of -10 ℃ ~ 40 ℃ , and during transportation and storage should be in the range of -25℃ to 55℃;

●The average relative humidity <90%;;

 ●Power supply quality: Supply voltage fluctuation range of 415 ± 10%. Unbalanced ≤ 5%, the grid frequency fluctuations is not greater than ± 2%.

 ●Water-cooled machine need to install water switch in the position of intake and outlet of water. Be sure to use soft water, and keep waterways smooth without visible particulate impurities, and the water pressure should be maintained at between 0.2MP ~ 0.3MP, water temperature between 25℃-30 ℃.

 ●When the ambient temperature ≤ 0 ℃ ,the machine needed for a long time to stop running, be sure to drain the internal water to prevent water freezing or frost crack of the water pipe blockage.

  • details

Main Specifications

a. Input voltage: Three-phase AC 415V ± 10%  50Hz

b. Maximum input current: AC 680A

c. Power factor: ≥0.9; Efficiency: ≥85%

d. Output characteristics: constant current / constant voltage

e. Output voltage: DC 0 ~ 12V

f. Output Current: DC 0 ~ 36000A

g.  Stabilized current accuracy≤1%; Stabilized voltage accuracy ≤1%;Current sharing accuracy ≤1%

h. Ripple factor: ≤3%